A full-size ASIC miner draws as much power as an electric oven, all day, every day. Getting the electrics right is the difference between a safe, profitable setup and a melted plug. This guide covers voltage, current, circuits, cords and the rules electricians use.
Electrical work must be designed and installed by a licensed electrician to your local code. Use this guide to plan and to ask the right questions, not to do the wiring yourself.
Watts, volts and amps
Power (watts) = voltage × current (amps) × power factor. ASIC power supplies have a power factor close to 1, so a 3,500 W miner draws about 14.6 A at 240 V, but about 29 A at 120 V. That is why full-size miners run on 200 to 240 V: half the current means thinner cables, smaller breakers and less heat in the wiring.
- Most current ASIC PSUs accept roughly 200 to 240 V; some industrial models accept up to 277 V or 380 to 415 V three-phase.
- Small home and solo miners run on normal 100 to 240 V outlets.
- Check the label on the PSU for its exact input range before you plug in.
The 80% rule for continuous loads
Miners run continuously, so in many codes (such as the US NEC) a circuit should carry no more than 80% of its breaker rating. A 20 A circuit carries 16 A of miners; a 30 A circuit, 24 A. At 240 V, one 3.5 kW miner (14.6 A) fits on a 20 A circuit; two fit on a 40 A circuit.
Plan your circuits
Cords, plugs and PDUs
- Match the inlet. ASIC PSUs commonly use C13 (up to about 10 to 15 A) or C19 (up to about 16 to 20 A) inlets. Use a C19 cord for high-current units.
- Rate the cord for the current. Use heavy-gauge cords rated above the miner’s draw, as short as practical.
- No household power strips or extension reels. They are not rated for continuous high loads and are a common cause of fires.
- Use proper PDUs (power distribution units) rated for the total load in multi-miner setups.
- Check connections for heat with an infrared thermometer after the first hours and regularly after that.
Single-phase or three-phase?
Homes usually have single-phase supply. Larger sites use three-phase, which delivers more power over the same cables. Miners on three-phase are connected phase-to-phase or phase-to-neutral depending on the voltage, and the load should be balanced evenly across the three phases.
How much capacity do you have?
A typical house service might be 100 to 200 A at 240 V, shared with everything else in the home. One or two full-size miners can fit; ten will not. Ask an electrician to calculate your spare capacity before you buy, and check your supply contract for limits.
Dedicated circuit sized with the 80% rule · correct voltage for the PSU · cord rated for the current · no power strips · earth/ground connected · connections checked for heat after an hour.
ASIC power checklist before you plug in
Before you connect a miner, check four things. First, the ASIC power supply input range on the label matches your voltage. Second, the circuit and breaker are rated for the continuous current with the 80% margin. Third, the cord and plug are rated for the current, with the right inlet such as C19 for high-current units. Fourth, nothing else heavy shares the circuit.
Then watch the first hours. Feel the plug and cord after an hour of running: warm is normal, hot is not. A loose or undersized connection is the most common cause of melted plugs. If you are planning more than one or two miners, use the power and circuit planner to size the whole ASIC power setup and take the results to your electrician.
Questions, answered
Can I plug a miner into a dryer or EV outlet?
Those outlets are 240 V, but they may already be in use, the circuit may be shared, and the plug type will need a proper adapter cord. Ask an electrician.
Do miners need a UPS?
No. Miners restart automatically after power returns. A small UPS for your router keeps monitoring online.
What about power surges?
Surge protection at the panel is a good idea for sites with unstable supply.